About Us »» Equipments
Equipments
Imageology  
    Imaging Modes
  • 2D
  • M-Mode
  • PW Doppler
  • CW Doppler
  • Color Doppler
  • Power Doppler (Angio)
    Features
  • Programmable color Touch Screen
  • Anatomical M-Mode
  • Easy and Advanced 3D
  • Report Writer (for customizable reports)
  • Cine Review
  • On-board storage
  • USB port for Flash drive (memory stick)
  • for transferring images, loops, and reports
  • Coded Harmonics (Tissue Harmonics)
  • Solid penetration
  • Single-button color optimization
  • Fast boot up
  • Automatic probe selection by application
  • CW Doppler for cardiac applications
  • Advanced Urology reporting
  • Phase-inversion harmonics for better contrast
GE (USA) LOGIQ 3 Fetal Echocardiogram, Fetal Brain US Scan
GE(USA)LOGIQ400 Orbit US Scan, Thyroid US Scan, Musculoskeletal US Scan
GE(USA)LOGIQ 200 Carotid Doppler, DVT Doppler, Varicose Veins Doppler
 
OLYMPUS-AU400  
  • Fully automated, for routine, STAT, urine and homogeneous Immuno Assays
  • Clinical chemistry and immunological parameters. End point, kinetic assays, fixed-time-kinetics, optionally ISE methods
  • Through put is 400 photometric tests / hour; maximum of 800 with ISE
  • Racks with 10 samples each (bar-codes on primary tubes and on racks); capacity of 80 samples; continuous loading
  • Full uni- and bidirectional communication possible
  • Up to 22 positions for STAT samples, bar-coded primary tubes
 
ADVIA CENTAUR CP  
  • Random access immunoassay system (Chemiluminescence)
  • 180 tests/hour throughput
  • 400 test walk-away capability
  • 15 refrigerated onboard reagents
  • 84 sample onboard capacity
  • Time to first results is 15 minutes
  • Walk away time is 1 Hr Minimum
  • No pause loading/unloading of samples reagents and consumables
 
ADVIA CENTAUR IMMUNUOASSAY SYSTEM  
  • No daily start-up
  • No-pause loading/ unloading of samples
  • True STAT capability
  • On-board reagent refrigeration
  • 30 assays on board
  • Automated daily cleaning, on your schedule
  • Disposable pipette tips to eliminate carry-over
  • Clot detection and sample management capability
  • No-pause loading of reagents, ancillaries and consumables
  • Throughput up to 240 tests per hour
  • On-board dilution, repeat and reflex testing without operator intervention
  • Direct to track sampling - no robotic interface necessary
  • Universal design
  • Accommodates single-tube or rack-based sample transport system
  • Independent operation available at all times
  • Unrestricted operator access to all reagents, samples and supplies
 
Biorad 680-Elisa Reader  
  • Measurement Range: 0.000- 3.500 OD
  • Single & Dual Wavelength Reading methods
  • Wavelength range of 400-750 nm
  • Filter Capacity of 8 interference filters
  • 415, 450, 490 & 655 nm standard filters
  • RS-232C Bidirectional Computer Interface
  • Optical Sensor of 8 Silicon diode for measurement & one for reference
 
EASYLYTE-
Sodium-Potassium Analyzer
 
  • Whole blood, Serum, Plasma, Urine can be used
  • Analysis time is 60 sec (Blood)90 sec (Urine
  • Data Storage is 100 patient results,20 normal QC results,20 abnormal QC results
  • Reproducibility is Typical Within Run (n=20)
    Blood, Serum, Plasma:
    Na+: CV < 1% (80-200 mmol/L)
    K+: CV < 2% (1-10 mmol/L)
    Urine:
    Na+: CV < 5% (80-200 mmol/L)
    K+: CV < 5% (1-10 mmol/L)
  • Calibration is completely automatic and electrodes are maintenance free with long life.
 
MICRO LAB 300  
  • Small sample size gives low running costs
  • Built in micro sipper system
  • 12 position filter wheel covers all routine tests
  • All end-point, two point, bichromatic and kinetic tests are possible
  • Non linear tests also possible
  • Rapid temperature control
  • Fully programmable with up to 60 methods
  • Built in quality control package
  • Built in printer
  • Qwerty keyboard to input sample names
  • Allows profile testing
  • Reports all results by patient
  • Interfaces to main computer
 
SYSMEX KX-21-
Haematology Analyzer
 
  • Daily maintenance is automatically performed by the instrument with every start up and shut down
  • Throughput is up to 60 samples per hour
  • Sample volume needed is Whole Blood Mode : 50µL Pre-dilute Mode : 20µL
  • Parameter are WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, NEUT%, LYMPH%, MXD%, NEUT#, LYMPH#, MXD#, RDW-SD, PDW*, MPV, P-LCR*